- Solar Products
- -Solar Module
- -Solar Lamp
- -Solar Fan Caps
- -Solar Products For Family
- -Solar Rechargeable Fans
- -Solar Supporting Products
- -Solar Products For Industry
- -Solar Bag
- Proximity Switch And Sensor
- -Inductance Type Proximity Angular column type
- -Inductance Type Proximity Cylindrical Type
- -IC Capacitive Proximity Switches
- -Capacitance Proximity Switch
- -Photoelectric Switch
- Low Voltage Electrical Products
- -AC Contactor
- -Mini Ciruit Breaker
- -Relay
- -Surge Protective Device
- -Residual Current Device
- -Fuse
- -Moulded Case Circuit Breaker
- Meter Series
- -Electronic Meter
- -Mechanical Meter
- -Temperature Controller
- Switch And Socket
- -Floor Socket
- -Universal Adapter
- -Wall Switches
- Plastic Products
- -Cable Connector
- -Cable Clamps Tie Mounts
- -Terminal Block
- -Heat-Shrinkable Tubings
- -Cable Clip
- -Nylon Cable Ties
- Pushbuttons
- Indicator Light
- Isolating Switch
- Toggle Switch

Assemble and defend
Series of products applies to equipment fore-end
The protection implement applies to interior installation , installation adds water-proof facilities of dress outside be obliged to
Be obliged to solid and reliable electricity of all connection connection, lightning protection ground connection responds to a magic figure
Agree well with the lightning protection standard request. Ground connection achieves to the full short but straight
May demand to be custom-made according to the customer
Applicable scope
The OBVU9 series electricity wells up the protector (to hereafter refer to as SPD) to be suitable in exchanging 50/60Hz, the voltage 220V single-phase power supply system, uses the electric appliance to the electrical appliances and the similar place, appears the question indirect thunder and lightning and the direct thunder and lightning influence or other instantaneous overvoltage when the line carries on the load two levels of protections.
SPD conforms to GB18802.1-2002/IEC61643-1.1998å’ŒYD/T1235.1-2002.
Installs and uses
1, installs in LPZ2 or the LPZ3 area intersection point, with enters the terminal SPD according to the cascade way arrangement, the connection copper nature wire is 1~4mm2, its length is not bigger than 500mm.
2nd, SPD each must establish the protection - use fuse or the small circuit breaker extremely.
The contour and installs the size
Main technical parameter
voltage running voltage Un:220V~
most greatly continually working voltage Uc:320V~
voltage protection level UP:1kV
biggest discharging current Imax:8kA(8/20us)
nominal discharging current In:5kA(8/20us)
response time <25ns
working conditions Temperature: - 5℃~+45℃
Relative temperature: ≤95%
Ordering notice
When ordering must indicate SPD the model, the specification and quantity.