- Solar Products
- -Solar Module
- -Solar Lamp
- -Solar Fan Caps
- -Solar Products For Family
- -Solar Rechargeable Fans
- -Solar Supporting Products
- -Solar Products For Industry
- -Solar Bag
- Proximity Switch And Sensor
- -Inductance Type Proximity Angular column type
- -Inductance Type Proximity Cylindrical Type
- -IC Capacitive Proximity Switches
- -Capacitance Proximity Switch
- -Photoelectric Switch
- Low Voltage Electrical Products
- -AC Contactor
- -Mini Ciruit Breaker
- -Relay
- -Surge Protective Device
- -Residual Current Device
- -Fuse
- -Moulded Case Circuit Breaker
- Meter Series
- -Electronic Meter
- -Mechanical Meter
- -Temperature Controller
- Switch And Socket
- -Floor Socket
- -Universal Adapter
- -Wall Switches
- Plastic Products
- -Cable Connector
- -Cable Clamps Tie Mounts
- -Terminal Block
- -Heat-Shrinkable Tubings
- -Cable Clip
- -Nylon Cable Ties
- Pushbuttons
- Indicator Light
- Isolating Switch
- Toggle Switch

Product Description
LS-C series surge protective deviceis suitable for TN-S、TN-C-S、TT、IT etc. power supply system of AC 50/60Hz、≤380V, insalled on the joint of LPZ1 or LPZ2 and LPZ3 , it's designed according to IEC61643-1、GB18802.1, it adopts 35mm standard raill,there is a failure release mounted on the module of surge protective device,When the SPD fails in breakdown for over-heat and over-current, the failure release will help electric device separate fron the power supply system and give the indication signal, green means normal, red means abnormal,it's also could be replaced for the module module when has operating voltage.
Product Features
1 、Imcluding over-current and over-heat protection, temperature control circuit break technical.
2、Module design, convenient installation, could be replaced online.
3、Smal lesk current, quick response, less residual voltage.
4、Signal in dication device, green (normal), red (abnormal).
5、New technology, high energy, clearance discharge pole (N-PE)
Main Technical Parameters
| Technical Parameters | Model | |||||||||||||
| LS-40 | LS-30 | N-PE | ||||||||||||
| Rated Operating Voltage Un (V~) | 110V | 220V | 380V | 220V | 380V | 220V | 380V | |||||||
| Maximum Continuous Operating Voltage Uc (V~) | 140V | 320V | 320V | 385V | 420V | 440V | 320V | 320V | 385V | 420V | 440V | 255V | ||
| Voltage Protection Level Up (V~)kV | ≤0.8 | ≤1.0 | ≤1.4 | ≤1.5 | ≤2.0 | ≤2.0 | ≤1.0 | ≤1.4 | ≤1.5 | ≤2.0 | ≤2.0 | ≤1.0 | ≤1.5 | |
| Nominal Discharge Current ln (8/20μs)kA | 20 | 15 | 20 | 40 | 60 | |||||||||
| Maximum Discharge Current lma×(8/20μs)kA | 40 | 30 | ||||||||||||
| Response time ns | <25 | |||||||||||||
| Test Standard | GB18802、 IEC61643-1 | |||||||||||||
| L/N(mm2) The Cross Section of L/N Line | 10 、16 | 10 | ||||||||||||
| PE(mm2) The Cross Section of PE Line | 10、25 | 16 | ||||||||||||
| Fuse or Switch (A) | 32A | 25A、32A | ||||||||||||
| Operating Environment℃ | -40℃~+85℃ | |||||||||||||
|
Relative Humidity (25℃) |
≤95% | |||||||||||||
| Installation | Standar Rail 35mm | |||||||||||||
| Material of Outer Covering | Fiberglass | |||||||||||||