- Solar Products
- -Solar Module
- -Solar Lamp
- -Solar Fan Caps
- -Solar Products For Family
- -Solar Rechargeable Fans
- -Solar Supporting Products
- -Solar Products For Industry
- -Solar Bag
- Proximity Switch And Sensor
- -Inductance Type Proximity Angular column type
- -Inductance Type Proximity Cylindrical Type
- -IC Capacitive Proximity Switches
- -Capacitance Proximity Switch
- -Photoelectric Switch
- Low Voltage Electrical Products
- -AC Contactor
- -Mini Ciruit Breaker
- -Relay
- -Surge Protective Device
- -Residual Current Device
- -Fuse
- -Moulded Case Circuit Breaker
- Meter Series
- -Electronic Meter
- -Mechanical Meter
- -Temperature Controller
- Switch And Socket
- -Floor Socket
- -Universal Adapter
- -Wall Switches
- Plastic Products
- -Cable Connector
- -Cable Clamps Tie Mounts
- -Terminal Block
- -Heat-Shrinkable Tubings
- -Cable Clip
- -Nylon Cable Ties
- Pushbuttons
- Indicator Light
- Isolating Switch
- Toggle Switch

Application
DZ47-63 Series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system. The product is novel in structure,light in weight,reliable and excellent in performance.It has high breaking capacity,can trip quickly and it's installation uses with guide,its case and body are adopted with high fire-resistartant and shockproof plastics.The product,with long life,is mainly used in AC 50HZ/60HZ single-pole 240V or two,three,four-pole 415V circuit for overload and short-circuit protection as well as for unfrequent on-and -off switching electric equipment and lighting circuit in normal case.This product confoms to GB 10963,IEC60898,BS3781.
Specifications
| Standard | Rated current(A) | Pole | Voltage(V) | Breaking capacity(A) |
| BS3781-1 IEC60898 |
1 to 40 50 to 60 |
1 | 240 | 6000 |
| 2,3,4 | 415 | 6000 | ||
| 50 to 60 | 1 | 240 | 4000 | |
| 2,3,4 | 415 | 4000 | ||
| IEC157-1 | 1 | 1 | 220/240 | 10000 |
| 2,3,4 | 220/240 | 20000 | ||
| 2,3,4 | 380/415 | 10000 | ||
| 3 | 1 | 220/240 | 8000 | |
| 2,3,4 | 220/240 | 20000 | ||
| 2,3,4 | 380/415 | 8000 | ||
| 10 to 40 | 1 | 220/240 | 7000 | |
| 2,3,4 | 220/240 | 16000 | ||
| 2,3,4 | 380/410 | 8000 | ||
| 50 | 1 | 220/240 | 6000 | |
| 2,3,4 | 220/240 | 10000 | ||
| 2,3,4 | 380/410 | 6000 | ||
| 60 | 1 | 220/240 | 5000 | |
| 2,3,4 | 220/240 | 10000 | ||
| 2,3,4 | 380/410 | 5000 | ||
| BS3781-1 IEC60898 |
1 to 40 | 1 | 240 | 4000 |
| 2,3,4 | 415 | 4000 | ||
| IEC157-1 | 1 to 40 | 1 | 220/240 | 6000 |
| 2,3,4 | 220/240 | 12000 | ||
| 2,3,4 | 380/415 | 6000 |
Rated temperature 40℃
Rated voltage 240/415V AC
Rated current(C):1,3,5,6,10,15,16,20,25,32,40,50,60,63A
(D):1,3,5,6,10,15,16,20,25,32,40A
Electric endurance not lower than 6000 times
Mechanical endurance lower than 2000 times
Tropical test:2 kinds